Foxy® R2 Fraction Collectors

Foxy R2 and Foxy R2 High Flow fraction collectors uses two racks with radio frequency identification (RFID) to automatically detect collection rack​​s for easy setup.

Foxy® R1
Foxy® R1
touchscreen
Foxy® R1

The two-rack Foxy R2 fraction collector can be adapted to a broad spectrum of applications. The units can distribute fractions into 96 well microplates, standard tube sizes, and bottles. For essentially unlimited volumes, funnel racks can direct fluids to any collection vessel or downstream process. 

Standard Features

  • Collect peaks of interest separately using any combination of slope, level, and time window reliably separates peaks by monitoring detector output, so you don't have to expend glassware on no-interest effluent
  • Collect uniform fractions by time, drop count, or pumped volume
  • Stores up to 8 collectio​n methods
  • Choice of available racks (specify when ordering). 
  • Coldroom-friendly design 
  • Sturdy cast aluminum frame 
  • Easy to use symbolic touch screen interface 
  • Built-in Ethernet and RS-232 communication capabilities 
  • Faster tube changes 
  • µL delay volume between diverter valve and drop former 
  • Flow rates up to 125 mL/minute​

Get the Peaks You Want

Collect only the peaks you want by programming desired peak detector optio​ns.​​

Level Sens​​ing​​​
slope with horizontal line

Collect peaks above detector threshold, enabling “heartcut” collection of concentrated part of the peak.​

Slope​
slope with vertical bounds

Collect peaks based on inflection points. Separate close peaks by valley triggers.

Time​ Window
clock with time wedge

Collect only during a specific interval of time.

Del​ay Compensation
hour glass

Cut peaks at the diverter valve regardless of system tubing lengths.​​​​​​​

Slope-detected peaks

By combining Teledyne LABS' accurate peak detection with uniform fraction options, desired peaks may be collected, diverting other peaks and baseline effluent to waste. Time windows bracket desired peak fluids. Only desired peaks are collected!

Slope-detecgted peaks
​​​
F​​oxy R2
High​​ Flow F​​oxy R2
​Inlet Tubing and Flow Ra​tes
​1/8" OD (0.062" ID), 25–125 mL/min
(up to 25 mL/min with low flow option)
​1/4” OD (0.125" ID), up to 1 L/min ​
Maximum Tube Height
196 mm
​180 mm
Racks
​2, with RFID
​2, with RFID
​Maximum Tube Qty
​​288 12/13 mm tubes
​288 12/13 mm tubes
​Construction Materials
Racks:
Funnel Racks:
Diverter Valve:
Construction:
Drip Tray:
Drop Former:​

Stainless steel and polypropylene
ECTFE (Halar) or ETFE (Tefzel) funnels
PEEK and FFKM (fluoroelastomer)
Cast Aluminum
Polypropylene
PEEK
Solvent Compatibility
​Aqueous and Organic
​Test Tube Time Change
​0.10 – 0.58 seconds (dependent on collection vessel tube advance speed)
Memory
​Eight methods​
Collection Modes
Time:
Drop:
Volume:

00:00:01– 99:59:59, 1 second intervals
1– 999 drops per fraction
Up to 999 units
​Peak Detection
​Slope, Threshold, Three time windows, Combination of any of the above collection modes
​​System Control
​Front panel touch screen, Ethernet or RS-232
Inputs
​Pump counter, external peak, inject, tube advance: +3.3 to 5 VDC or contact closure, active low, 30 ms minimum, 5 VDC max. Analog peak voltage: 0 to 1.0 V nominal, –1.2 to + 1.2 V usuable, –5 to +5 V max.
Outputs
​Pump pause/stop and event (tube change), 300 ms: open collector, active low, 15 VDC/100 mA maximum.
Automatic Shut-off
​Rack full, last tube, end of time window or external signal 
Security Valve (2-way)
​n/a
Diverter Valve (3-way)
​Included
Valve Pressure Rating
​0– 28 ps
Dimensions (W x H x D)
​12.25 x 14.0 x 13.0 in
31.1 x 35.5 x 33.0 cm
​12.25 x 14.9 x 21.0 in
31.1 x 37.8 x 53.3 cm
Weight
​7.1 kg (15.6 lbs) 
​10.3 kg (22.8 lbs)
​Power Requirements
​100 – 240 VAC, 50–60 Hz, 1 ampere max.
Includes one IEC power cord supplied for regional AC power (100, 117, 234 VAC)
Certification
​CE, CSA


Need Tech Support?