​An exceptionally stable and reliable fluorescence analyzer, the QuickTrace® M-8000 is based on the time-tested CVAF technique. The system is controlled by the Windows®-based, QuickTrace​ Software, which was designed for efficient method configuration, sequence creation, reporting of results and multi-tasking. 

Additionally, cost-saving features such as shut down of the flowing rinse and slowing of the SnCl2 flow during gold trap desorption, result in saving thousands of dollars per year in reduced reagent and waste costs.

For ultra-trace analysis, Teledyne Leeman Labs recommends the addition of our autosampler enclosure to protect the samples from contamination (such as dust particles) that could possibly lead to errors in determination. Additionally the autosampler enclosure also protects your investment from harsh acid gases which are normally present in and around digested samples.

​​​​​The trip​le mode, no enrichment, single or double gold amalgamation QuickTrace M-8000 CVAF is the system of choice for labs wanting to meet the most stringent reporting limits for academic research or enhanced waste discharge limits demanded by the “Clean Water Act”.

  • ​​Non-foaming Gas Liquid Separator (GLS) with overflow prevention system
  • Automatic end of run and inactivity standby routines
  • ≤ 0.05 ng/L instrument detection limits
  • Advanced contamination control, over range and smart rinse features
  • Intuitive gas controls eliminating air infusion into the system during sample probe movements during mode 2 and 3 analysis
  • EPA 1631 and EPA 245.7 compliant (gold amalgamation modes)
  • “Smart Rack” technology
  • 12-roller 4-channel peristaltic​ pump
  • Sample volume 0.5 mL to > 50 mL
  • Unlimited QC sample positions

Performance

The QuickTrace M-8000 CVAF analyzer is designed for exceptional short and long-term stability. Using 25 mL or less of sample, an Instrument Detection Limit (IDL) less than 0.02 ng/L is typical using gold trap modes. When consuming less than 10 mL of sample, the M-8000 consistently achieves an IDL less than 0.1 ng/L in non-gold trap mode.

  • ​Ultra-trace Instrument Detection Limit (IDL) (≤0.05 ng/L)
  • Linearity greater than four orders of magnitude
  • Dynamic range <0.05 ng/L to >400 µg/L
  • In Mode 1, by response comparison to a 100 ng/L standard, the system exhibits <0.01% memory effect of a 1 mg/L standard, immediately following the ingestion of a 1 part per million (mg/L) sample
  • In Mode 1, without employing the system's smart rinse technology, the analyzer is ready to accurately measure a sample within four minutes following the ingestion of a 1 ppm sample
  • In Mode 2 and 3 - short-term precision (%RSD @ 95% Confidence) = 2.5% @ 5 ng/L, n=5​

Qui​​ckTrace® Software

Teledyne LABS has designed the multi-tasking QuickTrace® software package to be easy to learn, yet provide valuable features and flexibility while continuously adding customer requested features, truly making the software designed by the customer for the customer.

Learn More >

Sample Automation

Customers have the freedom to choose an autosampler for their mercury analyzer that will meet their laboratories sample load requirements. The ASX-280 and ASX-560 autosamplers are available for any QuickTrace™ Mercury Analyzers. Manual sampling is also available with the option to add autosamplers as sample demand increases. See Specifications for details.​

Methods

  • EPA Method 245.7
  • EPA Method 1631
  • SW 846-7474
  • EU Methods: Din ISO 16772
  • EN-12338
  • ISO 17852​

*For a full list of applicable​ methods contact your sales specialist.​​​

​Analyzer​​​
​Carrier Gas (Ar)
​Variable psi not to exceed 40 psi
​Power Requirements
​100-240 VAC ±10%, 50/60 Hz
Dimensions
20 cm H x 48 cm W x 60 cm D
​Weight
​37 lbs (16.8 Kg)
​Computer Interfaces
​RS-232 or USB 
​Minimum Comp​uter Requirements​
​Microsoft® Windows® 10
2 GB RAM for Microsoft® Windows® 10
Video running 1024x768 with 24-bit color
Pentium Dual Core 2.3 GHz
Two free communication ports, either serial and/or USB
Internet Explorer 4 or higher must be installed for the online Help to function
Autosampler
​ASX-280, ASX-560
​ASX Standard Autosampler​​

ASX​​-280
​ASX-560​
​Tray
​10 Standards, 2 Sample Racks
​10 Standards, 4 Sample Racks
​Capacity
​180 samples
​360 samples
​Dimensions
​62 cm x 35.5 cm x 55 cm (24.4” x 14” x 21.6”)
​62 cm x 58 cm x 55 cm (24.4” x 22.5” x 21.6”)
​Weight
​8.1 kg (17.8 lbs)
​11.7 kg (26 lbs)
​Computer Interfaces
​USB and/or RS-232
​USB and/or RS-232
​Power Requirements
​100-240 VAC, 47-63 Hz, 1.9A
​100-240 VAC, 47-63 Hz, 1.9A
​Optional Enclosure
​​ENC-280DC
ENC-560DC